{"title":"Perchloroethylene (PERC)","description":"\u003cp\u003eBuy perchloroethylene (PERC \/ tetrachloroethylene) in technical \u0026amp; ACS grades. SDS + COA from Alliance Chemical.\u003c\/p\u003e","products":[{"product_id":"perchloroethylene-pce-perc","title":"Perchloroethylene (PCE, PERC)","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003ePerchloroethylene (PCE, PERC) is a heavy, colorless, volatile liquid chlorinated hydrocarbon widely utilized across multiple industrial sectors. With its chemical formula C2Cl4 and CAS number 127-18-4, this chlorinated solvent offers exceptional stability and non-flammable characteristics, making it an invaluable asset in highly demanding operational environments. It exhibits a characteristic ether-like odor and has a high vapor density, meaning its vapors are heavier than air. This product is key for heavy-duty vapor degreasing, cold cleaning, and chemical synthesis.\u003c\/p\u003e\u003cp\u003eAs a premier Texas chemical distributor, Alliance Chemical supplies this high-purity chlorinated solvent to meet the rigorous demands of industrial manufacturers nationwide. This volatile organic compound is insoluble in water but highly miscible with most organic solvents, allowing it to easily dissolve fats, oils, greases, and waxes from metallic surfaces. Because of its stability, low viscosity, and high boiling point of 250 °F, industrial facilities depend on Perchloroethylene to achieve spotless surfaces in automated cleaning systems and precision metal fabrication processes.\u003c\/p\u003e\u003ch3\u003eWhy This Grade\u003c\/h3\u003e\u003cp\u003eIndustrial processes require a consistent, high-purity profile of Perchloroethylene to prevent operational failures and ensure chemical stability. While specific grade standards like ACS or USP are not applicable to standard technical-grade solvents, the purity of our Perchloroethylene is carefully maintained to exclude moisture and trace contaminants. Moisture in chlorinated solvents can lead to hydrolysis, generating small amounts of hydrochloric acid which corrodes storage tanks, processing equipment, and the very metal parts being cleaned.\u003c\/p\u003e\u003cp\u003eUsing an inferior or degraded solvent can lead to catastrophic failure modes in closed-loop vapor degreasing systems. Trace volatile residues can contaminate sensitive electrical components or leave microscopic films on aerospace parts, compromising downstream adhesion or coating processes. Choosing Alliance Chemical's controlled-purity Perchloroethylene prevents these costly solvent breakdown issues, ensuring your vapor degreasers run efficiently without premature solvent decomposition or equipment corrosion.\u003c\/p\u003e\n\u003cdiv class=\"chemical-profile\" data-source=\"canonical\"\u003e\n\u003ch3\u003eChemical Profile\u003c\/h3\u003e\n\u003cdl\u003e\n\u003cdt\u003eCAS Number\u003c\/dt\u003e\n\u003cdd\u003e127-18-4\u003c\/dd\u003e\n\u003cdt\u003eChemical Formula\u003c\/dt\u003e\n\u003cdd\u003eC2Cl4\u003c\/dd\u003e\n\u003cdt\u003eMolecular Weight\u003c\/dt\u003e\n\u003cdd\u003e165.8 g\/mol\u003c\/dd\u003e\n\u003cdt\u003eBoiling Point\u003c\/dt\u003e\n\u003cdd\u003e250 °F at 760 mmHg (NTP, 1992)\u003c\/dd\u003e\n\u003cdt\u003eMelting Point\u003c\/dt\u003e\n\u003cdd\u003e-2 °F (NTP, 1992)\u003c\/dd\u003e\n\u003cdt\u003eFlash Point\u003c\/dt\u003e\n\u003cdd\u003eNo flash point in conventional closed tester. °C\u003c\/dd\u003e\n\u003cdt\u003eSpecific Gravity\u003c\/dt\u003e\n\u003cdd\u003e1.63 at 68 °F (USCG, 1999) - Denser than water; will sink\u003c\/dd\u003e\n\u003cdt\u003eAppearance\u003c\/dt\u003e\n\u003cdd\u003ePerchloroethylene appears as a clear colorless volatile liquid having an ether-like odor. Noncombustible. Insoluble in water. Vapors heavier than air. Density approximately 13.5 lb \/ gal. Used as dry cleaning solvent, a degreasing solvent, a drying agent for metals, and in the manufacture of other chemicals.\u003c\/dd\u003e\n\u003cdt\u003eSolubility\u003c\/dt\u003e\n\u003cdd\u003eless than 0.1 mg\/mL at 63 °F (NTP, 1992)\u003c\/dd\u003e\n\u003cdt\u003eUN Number\u003c\/dt\u003e\n\u003cdd\u003eUN1897\u003c\/dd\u003e\n\u003cdt\u003eHazard Class\u003c\/dt\u003e\n\u003cdd\u003eClass 6.1\u003c\/dd\u003e\n\u003cdt\u003ePacking Group\u003c\/dt\u003e\n\u003cdd\u003eIII\u003c\/dd\u003e\n\u003cdt\u003eProper Shipping Name\u003c\/dt\u003e\n\u003cdd\u003eTETRACHLOROETHYLENE\u003c\/dd\u003e\n\u003cdt\u003eGHS Signal Word\u003c\/dt\u003e\n\u003cdd\u003eDanger\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp class=\"chemical-profile__note\"\u003e\u003cem\u003eValues sourced from Alliance Chemical's canonical chemistry registry. Certificate of Analysis (COA) per lot.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVapor degreasing in metal manufacturing to remove cutting oils, lubricants, and protective greases from fabricated components before surface finishing.\u003c\/li\u003e\n\u003cli\u003eDry cleaning solvent of choice for commercial textile facilities requiring deep soil extraction without damaging specialized synthetic fibers.\u003c\/li\u003e\n\u003cli\u003eChemical intermediate in the manufacture of fluorinated compounds, refrigerants, and other specialty chlorinated organic chemicals.\u003c\/li\u003e\n\u003cli\u003eMetal drying agent used to displace water from delicate metallic components after aqueous wash cycles or plating procedures.\u003c\/li\u003e\n\u003cli\u003eFormulation component in automotive aerosols, brake cleaners, and specialized adhesive mixtures requiring fast evaporation and strong solvent action.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHazmat \u0026amp; Shipping\u003c\/h3\u003e\u003cp\u003ePerchloroethylene is classified as a regulated hazardous material for transportation. Under the Department of Transportation (DOT) guidelines, this chemical is shipped under the proper shipping name TETRACHLOROETHYLENE, identified as \u003cstrong\u003eUN1897\u003c\/strong\u003e, \u003cstrong\u003eHazard Class 6.1\u003c\/strong\u003e (Toxic Substances), \u003cstrong\u003ePacking Group III\u003c\/strong\u003e. The GHS Signal Word is \u003cstrong\u003eDanger\u003c\/strong\u003e. It is critical to recognize the safety profile associated with this solvent, including its designation as a suspected carcinogen under hazard statement H351, and its toxic effects on aquatic life under hazard statement H411.\u003c\/p\u003e\u003cp\u003eDue to these regulated hazards, shipping requires strict compliance with hazmat packaging regulations. Transport containers must be appropriately labeled and secured to prevent accidental release or exposure during transit. Personnel handling this substance must utilize appropriate personal protective equipment (PPE) as dictated by GHS guidelines, including nitrile or Viton gloves, chemical splash goggles, and respirators in poorly ventilated areas to mitigate risk from hazardous vapors. Every shipment from Alliance Chemical is fully documented with a compliant shipping manifest, and the Safety Data Sheet (SDS) is provided with every order to ensure safe handling from dock to storage.\u003c\/p\u003e\u003ch3\u003eHandling \u0026amp; Storage\u003c\/h3\u003e\u003cp\u003ePerchloroethylene should be stored in a cool, dry, well-ventilated area away from direct sunlight, with temperatures ideally maintained below 100 °F to minimize vaporization. Compatible storage container materials include carbon steel, stainless steel, and Teflon, while contact with aluminum, zinc, and strong bases must be avoided due to potential reactive degradation. The product is noncombustible, but heat exposure can generate toxic fumes of phosgene and hydrogen chloride, requiring secure secondary containment to prevent any environmental release into soil or waterways.\u003c\/p\u003e\u003ch3\u003eOrder \u0026amp; Documentation\u003c\/h3\u003e\u003cp\u003eOur customer support team is ready to assist with bulk logistics, custom packaging, and technical specifications for your facility's requirements. A Certificate of Analysis (COA) is available upon request for every production batch to verify quality and purity parameters. To secure your supply of industrial-grade solvents, you can \u003ca href=\"\/pages\/contact\" class=\"cta-button\"\u003eRequest a Quote\u003c\/a\u003e today or \u003ca href=\"\/products\/perchloroethylene-pce-perc\"\u003eOrder Perchloroethylene Online\u003c\/a\u003e directly. You can also \u003ca href=\"\/pages\/safety-data-sheets\"\u003eDownload the SDS\u003c\/a\u003e to review full compliance protocols.\u003c\/p\u003e\u003ch3\u003eWhy Buy from Alliance Chemical\u003c\/h3\u003e\u003cp\u003eSince 1997, Alliance Chemical has supplied premium industrial chemicals from Taylor, Texas under CAGE Code 1LT50, with a COA and SDS included on every order. For industrial use only.\u003c\/p\u003e\n\u003c!-- PDP_ARTICLE_LINKS_START --\u003e\n\u003cdiv class=\"pdp-article-links\" style=\"margin-top:2rem;padding:1.5rem;border-top:1px solid #e5e5e5;\"\u003e\n  \u003ch3 style=\"margin:0 0 1rem 0;font-size:1.25rem;\"\u003eLearn more about Perchloroethylene (PCE, PERC)\u003c\/h3\u003e\n  \u003cul style=\"list-style:disc;padding-left:1.5rem;margin:0;\"\u003e\n    \u003cli\u003e\u003ca href=\"\/blogs\/articles\/the-ultimate-guide-to-industrial-solvents-applications-selection-and-safety\"\u003eThe Ultimate Guide to Industrial Solvents: Applications, Selection, and Safety\u003c\/a\u003e\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- PDP_ARTICLE_LINKS_END --\u003e\n\n\u003c!-- ac-canonical-specs:start --\u003e\n\u003cstyle\u003e.ac-cspec{margin:1.5rem 0}.ac-cspec h2{margin:1.25rem 0 .5rem}.ac-cspec__t{width:100%;border-collapse:collapse;font-size:.95rem}.ac-cspec__t th{text-align:left;width:38%;padding:.4rem .6rem;border:1px solid #e2e2ea;background:#faf9ff;font-weight:600}.ac-cspec__t td{padding:.4rem .6rem;border:1px solid #e2e2ea}.ac-cspec__h{margin:.5rem 0 0;padding-left:1.1rem}.ac-cspec__docs{margin:.75rem 0 0;font-size:.9rem}\u003c\/style\u003e\n\u003cdiv class=\"ac-cspec\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"ac-cspec__t\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCAS Number\u003c\/th\u003e\n\u003ctd\u003e127-18-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFormula\u003c\/th\u003e\n\u003ctd\u003eC2Cl4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMolecular Weight\u003c\/th\u003e\n\u003ctd\u003e165.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrade\u003c\/th\u003e\n\u003ctd\u003eTechnical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eForm\u003c\/th\u003e\n\u003ctd\u003eLiquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePercentage\u003c\/th\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAppearance\u003c\/th\u003e\n\u003ctd\u003eColorless liquid with a mild, sweet odor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSolubility\u003c\/th\u003e\n\u003ctd\u003eSlightly soluble in water, soluble in organic solvents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBoiling Point\u003c\/th\u003e\n\u003ctd\u003e121°C (249.8°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMelting Point\u003c\/th\u003e\n\u003ctd\u003e-22°C (-7.6°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eSafety \u0026amp; Handling\u003c\/h2\u003e\n\u003ctable class=\"ac-cspec__t\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDOT Proper Shipping Name\u003c\/th\u003e\n\u003ctd\u003eTETRACHLOROETHYLENE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUN Number\u003c\/th\u003e\n\u003ctd\u003eUN1897\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDOT Hazard Class\u003c\/th\u003e\n\u003ctd\u003e6.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePacking Group\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGHS Signal Word\u003c\/th\u003e\n\u003ctd\u003eWarning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGHS Pictograms\u003c\/th\u003e\n\u003ctd\u003eGHS07 (Irritant), GHS08 (Health Hazard), GHS09 (Environmental Hazard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cul class=\"ac-cspec__h\"\u003e\n\u003cli\u003eH315 Causes skin irritation\u003c\/li\u003e\n\u003cli\u003eH317 May cause an allergic skin reaction\u003c\/li\u003e\n\u003cli\u003eH319 Causes serious eye irritation\u003c\/li\u003e\n\u003cli\u003eH336 May cause drowsiness or dizziness\u003c\/li\u003e\n\u003cli\u003eH351 Suspected of causing cancer\u003c\/li\u003e\n\u003cli\u003eH411 Toxic to aquatic life with long lasting effects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ac-cspec__docs\"\u003eDocumentation: \u003ca href=\"https:\/\/docs.alliancechemical.com\/sds\/perchloroethylene-pce-perc\" rel=\"nofollow\"\u003eSafety Data Sheet (SDS)\u003c\/a\u003e · \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0588\/2734\/1866\/files\/perchloroethylene-pce-perc_57924ef5-b2ef-4706-b87f-b2c3b617735f.pdf?v=1772816865\" rel=\"nofollow\"\u003eTechnical Data Sheet (TDS)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- ac-canonical-specs:end --\u003e\n","brand":"Alliance Chemical","offers":[{"title":"1 Quart \/ 1 Quart Can","offer_id":41340667887658,"sku":"E0B-VFF-84U","price":26.4,"currency_code":"USD","in_stock":true},{"title":"1 Quart \/ 2 Quart Cans","offer_id":41340669329450,"sku":"GWQ-AR6-KF7","price":38.5,"currency_code":"USD","in_stock":true},{"title":"1 Quart \/ 4 Quart Cans","offer_id":41340669362218,"sku":"KY7-6CF-V06","price":52.92,"currency_code":"USD","in_stock":true},{"title":"1 Quart \/ 8 Quart Cans","offer_id":41340669394986,"sku":"BPF-49V-GV3","price":101.2,"currency_code":"USD","in_stock":true},{"title":"1 Gallon \/ 1 Gallon Can","offer_id":41340669427754,"sku":"A6-YQMP-ZELE","price":52.92,"currency_code":"USD","in_stock":true},{"title":"1 Gallon \/ 2 Gallon Cans","offer_id":41340669460522,"sku":"J0X-PX3-ESR","price":101.2,"currency_code":"USD","in_stock":true},{"title":"1 Gallon \/ 4 Gallon Cans Case","offer_id":41340669493290,"sku":"8PG-16G-Q4V","price":192.5,"currency_code":"USD","in_stock":true},{"title":"1 Gallon \/ 4 Gallons x 36 Cases","offer_id":41891047702570,"sku":"NCT-H9F-732","price":4700.0,"currency_code":"USD","in_stock":true},{"title":"5 Gallon \/ 5 Gallon Pail","offer_id":41884780691498,"sku":"UM-LFBH-WAD4","price":230.0,"currency_code":"USD","in_stock":true},{"title":"5 Gallon \/ 4 x 5 Gallon Pails","offer_id":41884780724266,"sku":"Y7Y-KBF-G86","price":850.0,"currency_code":"USD","in_stock":true},{"title":"5 Gallon \/ 36 x 5 Gallons (Pallet)","offer_id":41884780757034,"sku":"E9B-Q6P-ZX0","price":6900.0,"currency_code":"USD","in_stock":true},{"title":"55 Gallon \/ 55 Gallon Drum","offer_id":41340669657130,"sku":"DD-6LKU-OJDR","price":1900.0,"currency_code":"USD","in_stock":true},{"title":"55 Gallon \/ 4 x 55 Gallon Drums","offer_id":41340669689898,"sku":"YA5-RUE-BM8","price":7068.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/2734\/1866\/files\/perchloroethylene-quart_9f69ba8d-5e91-4c5b-b131-551013f5b941.jpg?v=1748983726"},{"product_id":"perchloroethylene-acs-grade","title":"Perchloroethylene ACS Grade","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\u003cp\u003ePerchloroethylene ACS Grade, also known as tetrachloroethylene (CAS 127-18-4), is a clear, colorless, volatile liquid with a characteristic ether-like odor. As a highly stable, noncombustible chlorinated solvent, it plays a vital role across multiple industrial supply chains. At Alliance Chemical, we distribute high-purity solvents to meet the strict demands of laboratory synthesis and high-tolerance industrial cleaning. This compound has a molecular formula of C2Cl4 and a molecular weight of 165.8, serving as a robust carrier for specialized processes where water solubility is not tolerated.\u003c\/p\u003e\u003cp\u003eThe physical properties of this compound make it highly valued as a heavy-duty degreasing solvent, a dry cleaning solvent, and a drying agent for metals. Because it is noncombustible and insoluble in water, it provides a safe, stable medium for processes requiring minimal moisture interference. With a high density of approximately 13.5 lb \/ gal, this chemical sinks below water, allowing for efficient separation in aqueous systems. Our clients buy \u003ca href=\"\/products\/perchloroethylene-acs-grade\"\u003ePerchloroethylene ACS Grade\u003c\/a\u003e to use in precision metal cleaning, chemical manufacturing, and laboratory extraction workflows where consistent performance is paramount.\u003c\/p\u003e\u003ch3\u003eWhy This Grade\u003c\/h3\u003e\u003cp\u003eACS Reagent Grade chemicals are manufactured to meet the strict analytical standards set by the American Chemical Society. This grade ensures a highly controlled specification profile, minimizing trace contaminants that can disrupt sensitive chemical reactions. When your process demands a highly purified solvent without unwanted stabilizers or high levels of volatile impurities, ACS Grade is the standard choice. Using a lower-grade solvent in analytical environments can result in failed quality control tests, damaged equipment, or unpredictable reaction kinetics.\u003c\/p\u003e\u003cp\u003eChoosing a lower-grade alternative, such as technical or industrial grade, can introduce volatile organic compounds or moisture that interfere with spectroscopic analysis or synthetic pathways. In metal finishing or precision degreasing, impurities in non-ACS grades can leave microscopic residues on critical parts, leading to adhesion failures in subsequent coating or plating processes. Alliance Chemical provides this premium ACS Grade to ensure maximum process integrity, eliminating the failure modes associated with off-spec solvent products.\u003c\/p\u003e\n\u003cdiv class=\"chemical-profile\" data-source=\"canonical\"\u003e\n\u003ch3\u003eChemical Profile\u003c\/h3\u003e\n\u003cdl\u003e\n\u003cdt\u003eCAS Number\u003c\/dt\u003e\n\u003cdd\u003e127-18-4\u003c\/dd\u003e\n\u003cdt\u003eChemical Formula\u003c\/dt\u003e\n\u003cdd\u003eC2Cl4\u003c\/dd\u003e\n\u003cdt\u003eMolecular Weight\u003c\/dt\u003e\n\u003cdd\u003e165.8 g\/mol\u003c\/dd\u003e\n\u003cdt\u003eBoiling Point\u003c\/dt\u003e\n\u003cdd\u003e250 °F at 760 mmHg (NTP, 1992)\u003c\/dd\u003e\n\u003cdt\u003eMelting Point\u003c\/dt\u003e\n\u003cdd\u003e-2 °F (NTP, 1992)\u003c\/dd\u003e\n\u003cdt\u003eFlash Point\u003c\/dt\u003e\n\u003cdd\u003eNo flash point in conventional closed tester. °C\u003c\/dd\u003e\n\u003cdt\u003eSpecific Gravity\u003c\/dt\u003e\n\u003cdd\u003e1.63 at 68 °F (USCG, 1999) - Denser than water; will sink\u003c\/dd\u003e\n\u003cdt\u003eAppearance\u003c\/dt\u003e\n\u003cdd\u003ePerchloroethylene appears as a clear colorless volatile liquid having an ether-like odor. Noncombustible. Insoluble in water. Vapors heavier than air. Density approximately 13.5 lb \/ gal. Used as dry cleaning solvent, a degreasing solvent, a drying agent for metals, and in the manufacture of other chemicals.\u003c\/dd\u003e\n\u003cdt\u003eSolubility\u003c\/dt\u003e\n\u003cdd\u003eless than 0.1 mg\/mL at 63 °F (NTP, 1992)\u003c\/dd\u003e\n\u003cdt\u003eUN Number\u003c\/dt\u003e\n\u003cdd\u003eUN1897\u003c\/dd\u003e\n\u003cdt\u003eHazard Class\u003c\/dt\u003e\n\u003cdd\u003eClass 6.1\u003c\/dd\u003e\n\u003cdt\u003ePacking Group\u003c\/dt\u003e\n\u003cdd\u003eIII\u003c\/dd\u003e\n\u003cdt\u003eProper Shipping Name\u003c\/dt\u003e\n\u003cdd\u003eTETRACHLOROETHYLENE\u003c\/dd\u003e\n\u003cdt\u003eGHS Signal Word\u003c\/dt\u003e\n\u003cdd\u003eDanger\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cp class=\"chemical-profile__note\"\u003e\u003cem\u003eValues sourced from Alliance Chemical's canonical chemistry registry. Certificate of Analysis (COA) per lot.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUsed widely as a professional dry cleaning solvent in the textile industry to safely remove oils and grease from garments without damaging fabrics.\u003c\/li\u003e\n\u003cli\u003eApplied as a high-density vapor \u003ca href=\"\/pages\/industries\/metal-finishing\"\u003edegreasing solvent\u003c\/a\u003e for cleaning critical metal parts and components in aviation and manufacturing sectors.\u003c\/li\u003e\n\u003cli\u003eServes as an essential chemical intermediate and feedstock in the synthesis of fluorinated refrigerants and other chlorinated organic compounds.\u003c\/li\u003e\n\u003cli\u003eUtilized as a drying agent for metals, effectively displacing water from metal surfaces during intricate plating and finishing operations.\u003c\/li\u003e\n\u003cli\u003eDeployed in analytical laboratories for liquid-liquid extraction processes that require a heavy, non-flammable solvent with reliable physical characteristics.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHazmat \u0026amp; Shipping\u003c\/h3\u003e\u003cp\u003ePerchloroethylene ACS Grade is a regulated hazardous material. It must be transported under strict DOT guidelines as \u003cstrong\u003eUN1897, Hazard Class 6.1, Packing Group III\u003c\/strong\u003e. The Proper Shipping Name is \u003cstrong\u003eTETRACHLOROETHYLENE\u003c\/strong\u003e. With the signal word \u003cstrong\u003eDanger\u003c\/strong\u003e, this product carries hazard statements H351 (Suspected of causing cancer) and H411 (Toxic to aquatic life with long lasting effects). No GHS pictograms are applicable according to the canonical safety profile for this specific distribution entry, but compliance with standard safe handling rules for chlorinated hydrocarbons is mandatory.\u003c\/p\u003e\u003cp\u003eTo mitigate exposure risks associated with these hazard statements, appropriate Personal Protective Equipment (PPE) is required under OSHA regulations. Operators must wear chemical-resistant gloves (such as viton or nitrile), protective clothing, and splash-resistant safety goggles as specified under precaution P280. When working in confined spaces, a NIOSH-approved respirator is critical to prevent inhalation of heavy vapors. Every shipment is carefully packaged to comply with hazardous shipping regulations, and a comprehensive Safety Data Sheet (SDS) is provided with every order to ensure transport and site safety.\u003c\/p\u003e\u003ch3\u003eHandling \u0026amp; Storage\u003c\/h3\u003e\u003cp\u003eStore Perchloroethylene ACS Grade in a cool, dry, well-ventilated area away from direct sunlight, maintaining a temperature range below 95 °F to minimize vapor pressure buildup. Ensure container compatibility by keeping the solvent in its original steel or high-density polyethylene (HDPE) containers, as certain plastics will degrade when exposed to chlorinated solvents. This compound is highly incompatible with strong oxidizers, chemically active metals such as barium, lithium, and beryllium, as well as strong bases. Always keep containers tightly closed when not in use to prevent evaporation and exposure to the surrounding environment.\u003c\/p\u003e\u003ch3\u003eOrder \u0026amp; Documentation\u003c\/h3\u003e\u003cp\u003eAlliance Chemical makes sourcing high-purity reagents simple and reliable for commercial laboratories and industrial facilities alike. We ensure full transparency by offering a Certificate of Analysis (COA) available upon request for every batch we ship, verifying chemical purity and trace compound limits. For complete handling details, please consult the Safety Data Sheet (SDS) provided with every order of \u003ca href=\"\/collections\/solvents\"\u003esolvents\u003c\/a\u003e. To secure your supply, you can \u003ca href=\"\/pages\/contact\" class=\"cta-button\"\u003eRequest a Quote\u003c\/a\u003e for bulk volumes or \u003ca href=\"\/pages\/safety-data-sheets\"\u003eDownload the SDS\u003c\/a\u003e directly from our online portal.\u003c\/p\u003e\u003ch3\u003eWhy Buy from Alliance Chemical\u003c\/h3\u003e\u003cp\u003eSince 1997, Alliance Chemical has supplied premium industrial chemicals from Taylor, Texas under CAGE Code 1LT50, with a COA and SDS included on every order. For industrial use only.\u003c\/p\u003e","brand":"Alliance Chemical","offers":[{"title":"1 Quart \/ 1 Quart Can","offer_id":41340668346410,"sku":"1Q8-PGH-CS1","price":32.18,"currency_code":"USD","in_stock":true},{"title":"1 Quart \/ 2 Quart Cans","offer_id":41340669755434,"sku":"SKK-M57-6MA","price":51.47,"currency_code":"USD","in_stock":true},{"title":"1 Quart \/ 4 Quart Cans","offer_id":41340669788202,"sku":"GQ2-PCH-MA0","price":87.09,"currency_code":"USD","in_stock":true},{"title":"1 Quart \/ 8 Quart Cans","offer_id":41340669820970,"sku":"DVT-K99-M81","price":139.73,"currency_code":"USD","in_stock":true},{"title":"1 Gallon \/ 1 Gallon Can","offer_id":41340669853738,"sku":"7HY-YYD-TP1","price":77.0,"currency_code":"USD","in_stock":true},{"title":"1 Gallon \/ 2 Gallon Cans","offer_id":41340669886506,"sku":"A48-1DU-CE7","price":139.73,"currency_code":"USD","in_stock":true},{"title":"1 Gallon \/ 4 Gallon Cans Case","offer_id":41340669919274,"sku":"782-QX3-R69","price":260.0,"currency_code":"USD","in_stock":true},{"title":"1 Gallon \/ 4 Gallons x 36 Cases","offer_id":41891047669802,"sku":"7ZY-QJL-U8D","price":8500.0,"currency_code":"USD","in_stock":true},{"title":"5 Gallon \/ 5 Gallon Pail","offer_id":41884780560426,"sku":"Q2L-H4M-SZ7","price":330.21,"currency_code":"USD","in_stock":true},{"title":"5 Gallon \/ 4 x 5 Gallon Pails","offer_id":41884780593194,"sku":"8T9-1GE-L60","price":1162.34,"currency_code":"USD","in_stock":true},{"title":"5 Gallon \/ 36 x 5 Gallons (Pallet)","offer_id":41884780625962,"sku":"YM2-MDS-CXS","price":8559.01,"currency_code":"USD","in_stock":true},{"title":"55 Gallon \/ 55 Gallon Drum","offer_id":41340670083114,"sku":"8BA-4WG-T82","price":2959.5,"currency_code":"USD","in_stock":true},{"title":"55 Gallon \/ 4 x 55 Gallon Drums","offer_id":41340670115882,"sku":"L6W-UP5-SD2","price":10031.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0588\/2734\/1866\/files\/perchloroethylene-acs-quart_082f1bfa-190f-4ef8-8ec0-a6c1467035e0.jpg?v=1748983724"}],"url":"https:\/\/alliance-chemical-store.myshopify.com\/collections\/perchloroethylene.oembed","provider":"Alliance Chemical","version":"1.0","type":"link"}